XMT□-608
Technical specification
1, Measurement deviation:±0.5%F·S±1B,Cold end compensating deviation≤±2℃
2, Input(can be selected):CU50(-50~150)、PT100(-199~600)、K(-30~999)、E(-30~700)、J(-30~900)、T(199~400)
3, Relay output contact capacity: AC220V 5A(resistance load) period 2~120s can be adjusted.
4, Driving solid relay signal output, driving electric current >15m A; Voltage >9V, period is 2S
5, Power consumption AC85V~242V, 50/60HZ
6, Working environment, temperature 0~50.0℃, relative humidity≤85%RH, without corrode and strong electric radiation
Product code:
XMT □ 6 □ 8 □
(1) (2) (3) (4) (5)
(1) Frame dimensions (mm)
“A” = 96×96×110
“D” = 72×72×110
“E” = 48×96×110
“F” = 96×48×110
“G” = 48×48×110
“S” = 80×160×130
(2) “6” = Serial number, PV and SV display with 3 digits
(3) Alarms
“0” = no set alarm
“1” = one alarm of high limit
“2” = one alarm of low limit
(4) Input
“8” = universal input model
(5) Output
Blank = Relay contact output
“G” = solid state relay output